What is the reason why the temperature of industrial air cooled chiller cannot drop?
What is the reason why the temperature of industrial air cooled chiller cannot drop?
When the temperature of an industrial air-cooled chiller cannot drop, we usually conduct troubleshooting and maintenance from the following aspects:
1. Circuit fault
Check the circuit of the industrial air-cooled chiller system and whether the inlet and outlet pipelines of the cooling water are blocked; Check whether the valves in the cooling water pipeline are open and whether the cooling water flow and pressure are normal.
2. Electrical components
Check whether all electrical components are normal or stuck, and replace the damaged electrical components.
3. Solenoid valve
Check if the solenoid valve coil is working properly. If the solenoid valve is damaged, please replace it in a timely manner.
4. Panel
There is no output signal from the panel. Carefully check whether the circuit line is normal or replace it with a new component.
If the above reasons that may cause the temperature of the industrial chiller to not drop are ruled out, it is also necessary to check whether the condenser is blocked.
6. Wrong matching model
When the model of the industrial air-cooled chiller you choose does not match, resulting in insufficient cooling capacity, the temperature will not drop and the equipment cannot be cooled to achieve the desired cooling effect.
7. Unreasonable installation
If the temperature drop of an industrial air-cooled chiller cannot be reduced, the possible reason is that the water tower/water pump/pipeline has not been properly installed, resulting in the inability to reduce the temperature.
8. Temperature controller malfunction
When the temperature controller malfunctions, it is impossible to achieve temperature control on the device, resulting in abnormal temperature display of the temperature controller.
9. Blockage/leakage occurs
When the industrial air-cooled chiller unit is used for too long, it will cause fouling/blockage of the condenser/evaporator, poor water quality leading to pipeline blockage, refrigerant leakage, and other situations. So it will cause the temperature of the air-cooled chiller to not drop.
10. Environmental impact
When the environment is too high or too low, it will affect the cooling capacity of industrial air-cooled chillers, especially in cases where the environmental temperature is relatively harsh, which can seriously lead to the inability of the chiller to cool down.
Related recommendations
Chiller Classification and Analysis of Advantages and Disadvantages
610Chiller Classification and Analysis of Advantages and Disadvantages Chillers have many titles in the industry, including chillers, industrial chillers, screw chillers, scroll chillers, compa...
View detailsWhat is the reason why the water cooled chiller system does not cool?
504What is the reason why the water cooled chiller system does not cool? There may be several reasons why the water-cooled refrigeration system does not cool: 1. Insufficient coolin...
View detailsindustrial cooling systems chillers
17Industrial Cooling Systems: The Role of Chillers Industrial cooling systems are an essential part of many manufacturing and processing facilities, where maintaining precise temperatures is crit...
View detailsClosed Refrigeration and Heating Cycle Device
680Closed Refrigeration and Heating Cycle Device The closed refrigeration heating cycle device is used in industries with strict temperature requirements, which can combine heating and cooling ...
View details
HelloPlease log in