Semiconductor Chillers

Semiconductor Chillers

(TES series)

The device is used for fueling, lubricating oil cooling or heating when testing fuel, oil and the like for the test bench of Party A.

The heat transfer oil refrigeration heating device provides low temperature or high temperature heat transfer oil, and the heat transfer oil and the fuel oil exchange heat in the inlet heat exchanger of the test piece, so that the fuel can reach the desired temperature condition.

The secondary heat exchange completely solves the problem of temperature resistance of the fuel and oil delivery high pressure pump, and also solves the problem of fuel carbonization and coking caused by the excessive surface temperature of the heater.

ALL MODELS
ModelCooling CapacityHeating CapacityCirculating PumpPower
kWkWL/minkW
TES -45 ~ +250℃ series0.3 ~ 253 ~ 2525 ~ 1506 ~ 36
TES -85 ~ +200℃ series0.25 ~ 252.5 ~ 2520 ~ 1506.5 ~ 50
TES -60 ~ +200℃ series3 ~ 6015 ~ 60110 ~ 50028 ~ 102
Features of Semiconductor Chillers
  • Siemens S7-1200 PLC controller, support programming, 5 programs, each program 40 steps.
  • Danfoss, Emerson accessories (drying filter, oil separator, high and low pressure protector, expansion valve).
  • Emerson and other international brands are selected for refrigeration accessories, with stable performance.
  • PT100 or 4 ~ 20mA or communication given, USB and Ethernet interface, high adaptability.
  • The pressure of refrigeration system adopts pointer pressure gauge, and the pressure of circulating system is detected and displayed on the touch screen by pressure sensor.
  • With self diagnosis function, phase sequence protector, chiller overload protection, high voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
Advantages of Semiconductor Chillers
  • LNEYA represents the international advanced liquid temperature control technology, actively explores and studies component testing systems, mainly used for temperature test simulation in semiconductor testing, with wide temperature orientation and high temperature rise and fall, temperature range -92°C ~ 250°C, suitable for various Test Requirements. LNEYA is committed to solving the problem of temperature control lag in electronic components. Ultra high temperature cooling technology can be cooled directly from 300°C.
  • Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations at temperatures (-45°C to +250°C). Once put into practical use, these semiconductor devices and electronic products can be exposed to extreme environmental conditions to meet demanding military and telecommunications reliability standards.
Applications
  • Laboratories / Research Institutes
  • Universities / Colleges
  • Aerospace industry
  • Automotive Industry
  • Semiconductor and Electrical Industry
  • Chemical / Pharmaceutical Industry
  • Petrochemical Industry
  • Biochemical Industry
  • Medical Industry
  • Plastics Industry
  • Hospitals
  • Cannabis
  • R&D Workshop
  • Biotechnology Industry
  • Other Industries

Semiconductor Chillers-1

Semiconductor Chillers (Fluorinated Liquid)

(LTS series)

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

  • Non-flammable insulating liquid fluorinated liquid.
  • Wide operating temperature range and easy maintenance.
  • Ideal replacement for water, water glycol mixture, oil.

ALL MODELS
ModelAccuracyFlow ControlExpansion Valve Volume
L/minL
LTS -20 ~ +80℃ series±0.17 ~ 4510 ~ 20
LTS -40 ~ +80℃ series±0.17 ~ 4510 ~ 20
LTS -60 ~ +80℃ series±0.17 ~ 4510 ~ 20
LTS -80 ~ +80℃ series±0.17 ~ 4510 ~ 20
Features of Semiconductor Chillers
  • The pressure holding test of the medium circulation system is 7 bar.
  • Use high-quality magnetic pump without mechanical shaft seal.
  • Optimize temperature sampling and response speed, specially designed control algorithm, can respond quickly to stable temperature control.
  • Enhance the design of circulating pump capacity to meet the high-lift requirements of the system.
  • Continuous high temperature cooling technology meets the requirements of stable operation when heat is loaded on the heat sink plate and requires constant temperature control of cooling and heating.
  • In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.
Advantages of Semiconductor Chillers
  • The products not only provide good performance in many heat transfer applications without negatively impacting personal safety and environmental sustainability. Fluorinated liquid refrigeration and heating temperature control is a non-flammable insulating liquid fluorinated liquid, which has the characteristics of wide operating temperature range and easy maintenance.
  • It is an ideal substitute for traditional cooling liquids (such as water, water glycol or oil). The liquid fluoride refrigeration, heating and temperature control system has a wide range of applications, from the cooling of the semiconductor process to the cooling of aerospace electronic equipment.
Applications
  • Laboratories / Research Institutes
  • Universities / Colleges
  • Aerospace industry
  • Automotive Industry
  • Semiconductor and Electrical Industry
  • Chemical / Pharmaceutical Industry
  • Petrochemical Industry
  • Biochemical Industry
  • Medical Industry
  • Plastics Industry
  • Hospitals
  • Cannabis
  • R&D Workshop
  • Biotechnology Industry
  • Other Industries

Customized Solutions For Your Business

*
*
*
loading!
Submitted successfully!
Submit failed! Demo is not allowed to be submitted, please forgive me!
Mailbox error!
Phone error!