Search the whole station

KRYP -40 ~ +135°C Electronic Pump Temperature Control System

Electronic Pump Temperature Control System
-40 ~ +135°C Temperature Range
4 ~ 60kWCooling Capacity
24 ~ 95kWPower
±0.3°CAccuracy
7 / 10 inchColor Touch Screen
110 ~ 300L/minCirculating Pump

Features of Vehicle Test Chillers

  • Multi channel output, independent control of flow, no interference with each other.
  • Temperature, flow and pressure can be controlled separately.
  • Multi channel temperature control, and one device can achieve multi channel output, and control the flow separately.
  • Strong circulation pump ensures the delivery of high viscosity liquid, it can provide high flow under stable pressure.
  • Clear circuit, compact structure, multiple fault alarm functions to ensure safe operation of the equipment.
  • Temperature variation range is usually from -40 to 100 degrees (which can be extended to 150 degrees). While controlling the temperature, you can also choose to control the flow or pressure.
  • Equipped with powerful circulating pump to ensure the delivery of high viscosity liquid; Variable frequency regulation or proportional regulation valve is used to control the flow output to achieve high-precision control of 5% ~ 100% of the total range.
  • The temperature control equipment can be flexibly connected with other test platforms.

Advantages of Vehicle Test Chillers

automotive chillers

Multi Channel Temperature Control

KRY series automotive test chillers support multiple channel temperature control

  1. Independent flow and pressure control
  2. temperature, flow and pressure are controlled independently.

Display Function

  1. Display all the kind of process control temperatures.
  2. Shows the liquid level of the heat conducting medium in the expansion vessel.
  3. Shows indication for refrigeration system working.
  4. Shows indication for heater working.
  5. Shows indication for circulation pump working.
  6. Display the temperature control.
  7. The temperature upper limit, lower limit control can be set.
  8. The temperature difference between jacket & reactor material can be set.
  9. Shows the alarm to add the liquid when it is empty.
  10. The refrigeration compressor can be set to operate manually or automatically.
vehicle test chiller

Data Interface and Software

Standard configuration:

  1. PT100 temperature sensor input interface.
  2. USB export data interface.
  3. RS485 communication interface (MODBUS protocol).

Optional:

  1. 4 ~ 20mA Input interface for temperature measurement.
  2. 4 ~ 20mA Input interface for setting temperature.
  3. Ethernet interface.
  4. RS232 communication interface (MODBUS protocol).
  5. Profibus-DP interface.
  6. Computer operation software (optional Ethernet interface).
auto test system

Vehicle Performance Test

The new energy vehicle component test unit is mainly used for the offline detection of the drive motor of the new energy vehicle according to relevant test stanards and requuirements, it can test and simulate the performance requirements of motor in actual vehicle operation.

Products Parameters

 

Noted: Can provide customized services all types of equipment. Please consult us for details.

 

ModelKRYP-15W
KRYP-15
KRYP-25W
KRYP-25
KRYP-38WKRYP-60W
Temp Range-40℃~135℃-40℃~135℃-40℃~135℃-40℃~135℃
Tank volume60L100L200L300L
heating power15kW25kW38kW60kW
Refrigerating Output135℃15kW25kW38kW60kW
20℃15kW25kW38kW60kW
0℃15kW25kW38kW60kW
-20℃10kW16kW26kW37kW
-35℃4kW6.5kW10kW15kW
Temperature Control Accuracy±0.3℃
System pressure displayPressure of Refrigeration system is realized by pressure gauge (High pressure, low pressure);
The circulation system pressure is displayed on the touch screen by pressure sensor detection.
ControlerSiemens PLC and Fuzzy-PID Control Algorithm
Communicating ProtocolEthernet Interface TCP/IP Protocol
Internal Temp FeedbackEquipment tank internal temperature, refrigeration system condensation temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured)。
HeatThe maximum heating output power of the system (according to each model);
The heater has triple protection and independent temperature limiter to ensure the safety of heating system;
Heating power 10kW adopts regulator, heating power output control adopts 4~20mA linear control.
Refrigerating CapacityRefers to the ability to take away heat at different temperatures (ideal condition), the actual working conditions need to consider environmental heat dissipation, please enlarge properly, and do a good job of insulation measures.
High temperature cooling moduleIt is possible to cool the module from a high temperature of 150℃
Circulating pump flow   maxAdopt crown submagnetic drive pump / German brand magnetic drive pump
110L/MIN 2.5BAR150L/MIN 2.5BAR200L/MIN 2.5BAR300L/MIN 2.5BAR
Source 380V50HZ24kW max38kW max58kW max95kW max
Shape Size cm100*150*185100*150*185200*145*205200*145*205
CompressorEmerson Valley Wheel
EvaporatorPlate Heat Exchanger
Refrigeration AccessoryEmerson / Danfoss brand dry filter, pressure control, oil separator, etc.
Expansion ValveElectronic expansion valve
Operation Panel7-inch color touch screen, and the temperature curve shows the export of EXCEL data
Safe GuardingWith self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
RefrigerantR-404A/R507C
Electronic pump interfaceDN50 PN10 RFDN65 PN10 RFDN80 PN10 RFDN100 PN10 RF
Water-cooled type WType W is water cooled
Water-cooled CondenserDouble-pipe (heat) exchanger
Cooling Water 32℃7m³/H12m³/H17m³/H24m³/H
Shell materialCold rolled sheet spray (Standard Colour 7035)
Temperature spread-40℃~150℃

Other Products

  • KRY 0 ~ +100°C 1&3 Car Battery Cooler

    669

    0 ~ +100°C (optional: -40 ~ +100°C)Temperature Range11 ~ 60kWCooling Capacity22 ~ 68kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen3200 ~ 15000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Fe…

  • CNYL-5 Energy Storage Battery Chiller

    769

    ±0.5℃Temperature Accuracy5 ~ 8.5kWCooling CapacityR410ARefrigerant7 inchTouch Screen-45℃ ~ +55℃Ambient Operating Temperature CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Energy Storage Battery Chill…

  • KRYCH -40 ~ +100°C Automotive Battery Test Chamber Chiller

    676

    -40 ~ +100°C (or custom)Temperature Range4 ~ 15kWCooling CapacityR125/R507C/R404ARefrigerant±0.5°CAccuracy7 / 10 inchColor Touch Screen25m³/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Features o…

  • KRYH 0 ~ +160°C Oil Chillers

    736

    0 ~ +160°C (optional: -40 ~ +100°C)Temperature Range11~ 60kWCooling Capacity22 ~ 68kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen2800 ~ 12000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Fea…