Features of Semiconductor Chillers
- Siemens S7-1200 PLC controller, support programming, 5 programs, each program 40 steps.
- Danfoss, Emerson accessories (drying filter, oil separator, high and low pressure protector, expansion valve).
- Emerson and other international brands are selected for refrigeration accessories, with stable performance.
- PT100 or 4 ~ 20mA or communication given, USB and Ethernet interface, high adaptability.
- The pressure of refrigeration system adopts pointer pressure gauge, and the pressure of circulating system is detected and displayed on the touch screen by pressure sensor.
- With self diagnosis function, phase sequence protector, chiller overload protection, high voltage pressure switch, overload relay, thermal protection device and other safety protection functions.
Advantages of Semiconductor Chillers
Structure Design
A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature.
The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60℃.
Display Function
- Display all the kind of process control temperatures.
- Shows the liquid level of the heat conducting medium in the expansion vessel.
- Shows indication for refrigeration system working.
- Shows indication for heater working.
- Shows indication for circulation pump working.
- Display the temperature control.
- The temperature upper limit, lower limit control can be set.
- The temperature difference between jacket & reactor material can be set.
- Shows the alarm to add the liquid when it is empty.
- The refrigeration compressor can be set to operate manually or automatically.
Data Interface and Software
Standard configuration:
- PT100 temperature sensor input interface.
- USB export data interface.
- RS485 communication interface (MODBUS protocol).
Optional:
- 4 ~ 20mA Input interface for temperature measurement.
- 4 ~ 20mA Input interface for setting temperature.
- Ethernet interface.
- RS232 communication interface (MODBUS protocol).
- Profibus-DP interface.
- Computer operation software (optional Ethernet interface).
Configuration Software (Optional)
All dynamic temperature control system can be connected with the computer.
You can install and record the picture of display on the computer via the configuration software.
- Communication distance less than 200m.
- Easily temperature setting.
- Real time control screen.
- Curve records.
- Program selection.
- Alarm screen recording.
Products Parameters
Noted: Can provide customized services all types of equipment. Please consult us for details.
Model | TES-4525 | TES-4555 | TES-45A10 | TES-45A15 | TES-45A25 | |
TES-4525W | TES-4555W | TES-45A10W | TES-45A25W | TES-45A25W | ||
Temp. Range | -45℃~250℃ | -45℃~250℃ | -45℃~250℃ | -45℃~250℃ | -45℃~250℃ | |
Heating Power | 3kW | 5.5kW | 10kW | 15kW | 25kW | |
Refrigerating output | 250℃ | 3kW | 5.5kW | 10kW | 15kW | 25kW |
100℃ | 2.5kW | 5.5kW | 10kW | 15kW | 25kW | |
20℃ | 2.5kW | 5.5kW | 10kW | 15kW | 25kW | |
0℃ | 2.5kW | 5kW | 10kW | 15kW | 25kW | |
-20℃ | 1kW | 2.9kW | 6kW | 11kW | 16kW | |
-40℃ | 0.3kW | 0.9kW | 2kW | 3.8kW | 5.3kW | |
Temp. control accuracy of heat conduction medium | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ | |
System pressure display | The pressure of the refrigeration system is realized by the pointer type pressure gauge (high-pressure and low-pressure). | |||||
The circulation system pressure is displayed on the touch screen by pressure sensor detection. | ||||||
controller | Siemens PLC, Fuzzy PID Control algorithm with Cascade Control algorithm | |||||
Temp. control | Temperature Control Mode for outlet of Heat conduction medium; | |||||
External temperature sensor: (PT100 or 4~20mA or communication given) control mode (cascade control) | ||||||
Programmable | 10 procedures can be developed, and each program can be composed of 40 steps | |||||
Communicating protocol | Ethernet Interface TCP/IP Protocol | |||||
Internal temp. feedback of equipment | Equipment heat-conducting medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (configuration of water-cooling equipment) | |||||
External access temp. feedback | PT100 or 4~20mA or communication given | |||||
String-level control | The temperature difference between the outlet temperature and the external temperature sensor can be set and controlled; | |||||
Temp. difference control function | The temperature difference between the inlet temperature and the outlet temperature of the equipment can be set to be controlled (to protect the safety of the system). | |||||
Closed-cycle system | The whole system is a completely closed system with no oil mist at high temperature and no water in the air at low temperature. The system will not increase the pressure due to high temperature and automatically replenish the heat conduction medium at low temperature. | |||||
Heating Power | The maximum heating output power of the system (according to each model); | |||||
The heater has triple protection and independent temperature limiter to ensure the safety of heating system; | ||||||
The power is more than 10kW and the voltage regulator is adopted, and the heating power output control is controlled by 4-20mA linear control. | ||||||
Cooling capacity | It refers to the ability to carry away heat at different temperatures (in the ideal state). The actual working conditions need to be considered for environmental heat dissipation. Please enlarge it properly and do well the thermal insulation measures. | |||||
Circulation pump flow, pressure max | Magnetic drive pump | |||||
25L/min 2.5bar | 50L/min 2.5bar | 50L/min 2.5bar | 110L/min 2.5bar | 150L/min 2.5bar | ||
Compression engine | Tecumseh | Emerson / Danfoss | Emerson / Danfoss | Emerson / Danfoss | Emerson / Danfoss | |
Evaporimeter | Plate Heat Exchanger | |||||
Refrigeration Accessory | Danfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves) | |||||
Operation panel | LNEYA custom 7-inch color touch screen, temperature curve display\ EXCEL data export | |||||
Safe guarding | With self-diagnosis function; phase sequence phase breaker, freezer overload protection; high-voltage pressure switch, overload relay, thermal protection device and other safety protection functions. | |||||
Cryogen | R-404A / R507C | |||||
Interface size | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 RF | |
Shape size cm | 45*70*160 | 55*70*175 | 65*85*185 | 80*120*185 | 100*150*185 | |
Air-cooled type | It adopts copper tube aluminum fin condensation method, upper air outlet type, and the condensation fan adopts German EBM axial flow fan. | |||||
Water-cooled type W | Type W is water cooled | |||||
Water-cooled Condenser | Plate heat exchanger | |||||
Cooling water quantity at 25℃ | 1.1m3/h | 1.5m3/h | 2.6m3/h | 3.6m3/h | 7m3/h | |
Source 380V50HZ | 6kW max 220V | 9kW max | 16kW max | 23kW max | 36kW max | |
Source | Customizable 460V 60HZ, 220V 60HZ three-phase | |||||
Shell material | Cold rolled sheet spray (Standard Colour 7035) | |||||
Isolation explosion proof | Customizable isolation explosion proof (EXdIIBT4); | |||||
Installation License No. of Wuxi Guanzi Explosion-proof Product: PCEC-2017-B025 | ||||||
Barotropic explosion protection | A custom positive pressure explosion-proof (EXPXdmbIICT4) positive pressure system must be a water-cooled device; | |||||
Installation License No. of Wuxi Guanzi Explosion-proof Product: PCEC-2017-B025 |
Other Products
TES -85 ~ +200°C Semiconductor Refrigeration Chip
691-85 ~ +200°C (optional: -85 ~ +250°C)Temperature Range0.25 ~ 25kWCooling Capacity6.5 ~ 50kWPower±0.3°CAccuracy7 / 10 inchColor Touch Screen20 ~ 150L/minCirculation Pump CUSTOM DESIGN Leave a Message Email Us WhatsApp …
TES -60 ~ +200°C Semiconductor Coolers
630-60 ~ +200°C (optional: -85 ~ +250°C)Temperature Range3 ~ 60kWCooling Capacity28 ~ 102kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen110 ~ 500L/minCirculation Pump CUSTOM DESIGN Leave a Message Email Us WhatsApp …