Search the whole station

KRY -20 ~ +100°C 1&6 EV Battery Cooling System

EV Battery Cooling System
-20 ~ +100°C (optional: -40 ~ +100°C)Temperature Range
10 ~ 60kWCooling Capacity
36 ~ 75kWPower
±0.5°CAccuracy
7 / 10 inchColor Touch Screen
8000 ~ 20000L/HCooling Water

Features of Vehicle Test Chillers

  • Multi channel output, independent control of flow, no interference with each other.
  • Temperature, flow and pressure can be controlled separately.
  • Multi channel temperature control, and one device can achieve multi channel output, and control the flow separately.
  • Strong circulation pump ensures the delivery of high viscosity liquid, it can provide high flow under stable pressure.
  • Clear circuit, compact structure, multiple fault alarm functions to ensure safe operation of the equipment.
  • Temperature variation range is usually from -40 to 100 degrees (which can be extended to 150 degrees). While controlling the temperature, you can also choose to control the flow or pressure.
  • Equipped with powerful circulating pump to ensure the delivery of high viscosity liquid; Variable frequency regulation or proportional regulation valve is used to control the flow output to achieve high-precision control of 5% ~ 100% of the total range.
  • The temperature control equipment can be flexibly connected with other test platforms.

Advantages of Vehicle Test Chillers

automotive chillers

Multi Channel Temperature Control

KRY series automotive test chillers support multiple channel temperature control

  1. Independent flow and pressure control
  2. temperature, flow and pressure are controlled independently.

Display Function

  1. Display all the kind of process control temperatures.
  2. Shows the liquid level of the heat conducting medium in the expansion vessel.
  3. Shows indication for refrigeration system working.
  4. Shows indication for heater working.
  5. Shows indication for circulation pump working.
  6. Display the temperature control.
  7. The temperature upper limit, lower limit control can be set.
  8. The temperature difference between jacket & reactor material can be set.
  9. Shows the alarm to add the liquid when it is empty.
  10. The refrigeration compressor can be set to operate manually or automatically.
vehicle test chiller

Data Interface and Software

Standard configuration:

  1. PT100 temperature sensor input interface.
  2. USB export data interface.
  3. RS485 communication interface (MODBUS protocol).

Optional:

  1. 4 ~ 20mA Input interface for temperature measurement.
  2. 4 ~ 20mA Input interface for setting temperature.
  3. Ethernet interface.
  4. RS232 communication interface (MODBUS protocol).
  5. Profibus-DP interface.
  6. Computer operation software (optional Ethernet interface).
auto test system

Vehicle Performance Test

The new energy vehicle component test unit is mainly used for the offline detection of the drive motor of the new energy vehicle according to relevant test stanards and requuirements, it can test and simulate the performance requirements of motor in actual vehicle operation.

Products Parameters

 

Noted: Can provide customized services all types of equipment. Please consult us for details.

 

ModelKRY-2A25W/6SKRY-2A38W/6SKRY-2A60W/6S
Temp Range-20℃~+100℃
Temperature control precision±0.5℃±0.5℃±0.5℃
Temperature feedbackPt100Pt100Pt100
Temperature display0.01k0.01k0.01k
Flow control/Group1~20 L/min1~20 L/min1~40 L/min
Flow control accuracy/Group±0.2L±0.2L±0.2L
Number of fluid output groups6 groups6 groups6 groups
Pressure control/group0.2bar~2.5bar0.2bar~2.5bar0.2bar~2.5bar
Flow descriptionWhen the temperature control is lower than -30℃, the flow rate is controlled within 80% of the maximum value.
Flow pressure descriptionThe unit can control the flow individually or separately. Need to control different solutions at the same time (customized)
Heating Power15kW25kW38kW
cooling capacity100℃25kW38kW60kW
20℃25kW38kW60kW
0℃25kW38kW60kW
-20℃10kW15kW24kW
CompressionEmerson Valley Wheel Compressor
Expansion valve/solenoid valveElectronic expansion valve
Oil distributorEmerson
Dry filter, Pressure controlDanfoss
Evaporatorplate heat exchanger
Circulating pumpMagnetic drive pump
Frequency converterDelta
Flow,Pressure sensorElectromagnetic flowmeter, Johnson Controls pressure sensor
Input, Display10 inch color touch screen \ Siemens S7-1200 PLC controller
CommunicationModbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety protectionWith self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
 device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
Closed circulationThe whole system is a fully closed system, there will be no oil mist at high temperature, low temperature does not
systemabsorb water in the air, the system in operation will not because of high temperature pressure rise, low temperature
 automatically add heat conduction medium.
refrigerantR404A/R507C
Connection sizeThere are six groups of inlet and outlet,G3/4
Cooling water@20C8000L/H12000L/H20000L/H
Condenser(W)Shenshi tube type heat exchanger
Condenser(A)Optional air-cooled type, upper air outlet, the equipment size will be increased.
Power 380V50HZ36kW max51kW max75kW max
Dimension cm200*145*205200*145*205200*145*205
Weight(W)900kg1100kg1750kg
Optional220V 60HZ Three phase  400V 50HZ Three phase  440V 60HZ Three phase
OptionalExtend to -40~+135℃
OptionalThe size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp.

Other Products

  • KRY 0 ~ +100°C 1&3 Car Battery Cooler

    670

    0 ~ +100°C (optional: -40 ~ +100°C)Temperature Range11 ~ 60kWCooling Capacity22 ~ 68kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen3200 ~ 15000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Fe…

  • KRY -40 ~ +100°C 1&3 Battery Chiller

    715

    -40 ~ +100°CTemperature Range4 ~ 60kWCooling Capacity23.5 ~ 82kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen5000 ~ 18000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Vehicle Test…

  • KRYCH -40 ~ +100°C Automotive Battery Test Chamber Chiller

    676

    -40 ~ +100°C (or custom)Temperature Range4 ~ 15kWCooling CapacityR125/R507C/R404ARefrigerant±0.5°CAccuracy7 / 10 inchColor Touch Screen25m³/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Features o…

  • KRYP -40 ~ +135°C Electronic Pump Temperature Control System

    721

    -40 ~ +135°C Temperature Range4 ~ 60kWCooling Capacity24 ~ 95kWPower±0.3°CAccuracy7 / 10 inchColor Touch Screen110 ~ 300L/minCirculating Pump CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Vehicle Tes…

loading…