KRY 0 ~ +100°C 1&2 Battery Liquid Cooling System
Features of Vehicle Test Chillers
- Multi channel output, independent control of flow, no interference with each other.
- Temperature, flow and pressure can be controlled separately.
- Multi channel temperature control, and one device can achieve multi channel output, and control the flow separately.
- Strong circulation pump ensures the delivery of high viscosity liquid, it can provide high flow under stable pressure.
- Clear circuit, compact structure, multiple fault alarm functions to ensure safe operation of the equipment.
- Temperature variation range is usually from -40 to 100 degrees (which can be extended to 150 degrees). While controlling the temperature, you can also choose to control the flow or pressure.
- Equipped with powerful circulating pump to ensure the delivery of high viscosity liquid; Variable frequency regulation or proportional regulation valve is used to control the flow output to achieve high-precision control of 5% ~ 100% of the total range.
- The temperature control equipment can be flexibly connected with other test platforms.
Advantages of Vehicle Test Chillers
Multi Channel Temperature Control
KRY series automotive test chillers support multiple channel temperature control
- Independent flow and pressure control
- temperature, flow and pressure are controlled independently.
Display Function
- Display all the kind of process control temperatures.
- Shows the liquid level of the heat conducting medium in the expansion vessel.
- Shows indication for refrigeration system working.
- Shows indication for heater working.
- Shows indication for circulation pump working.
- Display the temperature control.
- The temperature upper limit, lower limit control can be set.
- The temperature difference between jacket & reactor material can be set.
- Shows the alarm to add the liquid when it is empty.
- The refrigeration compressor can be set to operate manually or automatically.
Data Interface and Software
Standard configuration:
- PT100 temperature sensor input interface.
- USB export data interface.
- RS485 communication interface (MODBUS protocol).
Optional:
- 4 ~ 20mA Input interface for temperature measurement.
- 4 ~ 20mA Input interface for setting temperature.
- Ethernet interface.
- RS232 communication interface (MODBUS protocol).
- Profibus-DP interface.
- Computer operation software (optional Ethernet interface).
Vehicle Performance Test
The new energy vehicle component test unit is mainly used for the offline detection of the drive motor of the new energy vehicle according to relevant test stanards and requuirements, it can test and simulate the performance requirements of motor in actual vehicle operation.
Products Parameters
Noted: Can provide customized services all types of equipment. Please consult us for details.
model | KRY-75/2S | KRY-A15/2S | KRY-A25W/2S | KRY-A38W/2S | KRY-A60W/2S | |
KRY-75W/2S | KRY-A15W/2S | |||||
Temp. Range | 0℃~+100℃ | |||||
Temp. control precision | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. feedback | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | |
Temp. display | 0.01k | 0.01k | 0.01k | 0.01k | 0.01k | |
Flow control/Group | 2~25 L/min | 2~25 L/min | 2~25L/min | 5~50 L/min | 5~50 L/min | |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L | ±0.2L | ±0.2L | |
Number of fluid output groups | 2 Groups | 2 Groups | 2 Groups | 2 Groups | 2 Groups | |
pressure control/Group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
flow pressure description | The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized) | |||||
Heating power | 10kW | 10kW | 15kW | 25kW | 38kW | |
cooling capacity | 100℃ | 10kW | 15kW | 25kW | 38kW | 60kW |
20℃ | 10kW | 15kW | 25kW | 38kW | 60kW | |
5℃ | 7kW | 11kW | 18kW | 27kW | 42kW | |
compression | Emerson Valley Wheel Compressor | |||||
expansion | Danfoss Thermal Expansion Valve/ Emerson Solenoid | |||||
oil distributor | Emerson | |||||
Dry filter, Pressure | Emerson/Danfoss | |||||
Evaporator | Danfoss/KAORI plate heat exchanger | |||||
Ciriulating pump | Nangfang centrifugal pump can be selected with imported brand magnetic pump | |||||
Frequency | Delta | |||||
Flow, Pressure sensor | German brand flowmeter, johnson Controls pressure | |||||
input, Display | 10 inch color touch screen \ Siemens S7-1200 PLC controller | |||||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | |||||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | ||||||
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available | |||||
Connection size | There are two groups of inlet and outlet,G3/4 | |||||
Cooling water at 20C° | 2600L/H | 3200L/H | 6000L/H | 9000L/H | 15000L/H | |
Condenser(W) | Shenshi tube type heat exchanger | |||||
Power 380V50HZ | 17kW | 20kW | 31kW | 43kW | 65kW | |
Dimension cm | 70*100*175 | 80*120*185 | 100*150*185 | 100*150*185 | 100*150*185 | |
Weight | 360KG | 450kg | 750kg | 1000kg | 1700kg | |
Optional | 220V 60HZ three phase 460V 60H three phase |
Other Products
KRY-O +5 ~ +135°C Oil Chiller Systems
742+5 ~ +135°C (optional: -40 ~ +100°C)Temperature Range15 ~ 38kWCooling Capacity63A ~ 125ACircuit Breaker±0.3°CAccuracy7 / 10 inchColor Touch Screen4000 ~ 8500L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp …
KRY 0 ~ +100°C 1&2 Battery Discharge Test
7330 ~ +100°C (optional: -40 ~ +100°C)Temperature Range1.8*2 ~ 60*2kWCooling Capacity9 ~ 120kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen5600 ~ 24000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp …
KRYCH -40 ~ +100°C Automotive Battery Test Chamber Chiller
677-40 ~ +100°C (or custom)Temperature Range4 ~ 15kWCooling CapacityR125/R507C/R404ARefrigerant±0.5°CAccuracy7 / 10 inchColor Touch Screen25m³/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Features o…
CHDYL-4 Energy Storage Cooling System for Charging Station
713±1℃Temperature Accuracy4kWCooling CapacityR134ARefrigerant7 inchTouch Screen-45℃ ~ +55℃Ambient Operating Temperature CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Energy Storage Cooling System for Ch…
loading…
已经是到最后一篇内容了!