Electronic Car Battery High and Low Temperature Coolant Test Chiller Descaling

For a long time, traditional cleaning methods such as mechanical methods, high-pressure water, chemical cleaning, etc., have many problems in cleaning, can not remove deposits such as scale, and cause corrosion to equipment, and residual acid will cause secondary corrosion to materials or corrosion under scale , If the scale cannot be cleaned in time, it will face the danger of equipment maintenance, shutdown, and even scrapping and replacement.

  1. Physical descaling equipment is a basic general-purpose instrument, which can prevent the formation of scale and protect the safety of the equipment without adding any chemicals.
  2. The physical descaling machine focuses on its functionality and is easy to install. The device prevents the formation of new scale and removes the old scale that has formed in the pipes.
  3. Electronic descaling and algaecide, and other different radical environmental impacts. The complete equipment is sealed and packaged with special materials to avoid adverse effects on the environment, which guarantees a long service life of the equipment (at least 20 years), and at the same time guarantees that it will not fail under high load conditions.
  4. To ensure the placement of the battery pack high and low temperature coolant test chiller, keep away from all kinds of dust, and to carry out regular cleaning, it is necessary to clean the environment and machinery and equipment, the dust is better organized, and the environment is timed. Monitoring to prevent various problems during use.
  5. Clean up the condensed water outside the battery pack high and low temperature coolant test chiller in time. When the air temperature is lower than the dew point temperature, condensate water is usually generated near the condenser and cooling water pipes. In rainy weather, the air humidity is low and condensation is easy to produce, posing a potential risk to nearby pipes and lines. Timely cleaning is conducive to the waterproof and moisture-proof of the equipment.
  6. Regularly check the condition of the water pump and pipeline interface. The pipeline of the chiller is complex, with both refrigerant channels and water circulation channels. Regularly check the external equipment and connections for leakage and damage, which is beneficial to prevent the leakage of cooling water from causing adverse effects on the equipment.

Latest News

  • water chiller efficiency

    129

    Introduction to Water Chiller Efficiency​ Water chillers are vital refrigeration systems that cool water (or water-glycol mixtures) for air conditioning, industrial processes (e.g., manufacturing, data center cooling), and equipment temperatur…

  • chiller rate

    146

    Introduction to Chiller Rate​ Chiller rate is a collective term describing the performance metrics that quantify a chiller’s ability to remove heat (cooling capacity) and its efficiency in doing so. Chillers are refrigeration systems that cool…

  • closed cycle cryocooler

    200

    Introduction to Closed Cycle Cryocoolers​ Closed cycle cryocoolers (CCCs) are specialized thermal management systems engineered to generate and sustain temperatures far below ambient, typically ranging from 0.1 K to 120 K (-273.05 °C to -153.1…

  • water cooled chiller types

    205

    Working Principle​Reciprocating water cooled chillers use reciprocating compressors. These compressors operate through the back – and – forth motion of a piston within a cylinder. The refrigerant is drawn into the cylinder during the intake strok…