How to maintain and maintain the industrial chiller systems?
How to maintain and maintain the industrial chiller systems?
1. Cleaning and replacing filters: Filters in industrial cooling systems can become clogged over time, affecting the cooling effect. Therefore, it is necessary to regularly clean or replace the filter to ensure the normal operation of the industrial cooling system.
2. Check the water pump: The water pump in the industrial cooling system is the core component of the cooling system, and it is necessary to regularly check the operation status of the water pump and whether there is any leakage in the pump body. Timely identify problems and repair or replace them.
3. Check the quality of coolant: The coolant in industrial cooling systems needs to be regularly checked for its quality, such as acidity, concentration, etc., to ensure that it meets the requirements. If the coolant quality is not qualified, it needs to be replaced in a timely manner.
4. Check the cooling tower: The cooling tower is an important component of the industrial cooling system, and it is necessary to regularly check the cleanliness and water flow rate of the cooling tower, and clean and repair it in a timely manner.
5. Check pipelines and valves: The pipelines and valves in industrial cooling systems need to be regularly checked for leaks or blockages, and repaired or replaced in a timely manner.
6. Check the control system: the control system in the industrial cooling system needs to be regularly checked for normal operation, such as whether the sensor is accurate, whether the control valve is normal, etc.
7. Regularly check the refrigerant system: Regularly check the pressure, temperature, and flow parameters of the refrigerant system of the low-temperature industrial refrigerator to ensure its normal operation.
8. Clean the condenser and evaporator: Regularly clean the interior and exterior of the condenser and evaporator of low-temperature industrial refrigerators to avoid dust accumulation and a decrease in heat dissipation efficiency.
9. Protection of motor: Regularly check the operation of the motor and electrical wiring of the low-temperature industrial refrigerator to ensure its stable operation.
10. Replace filter element and engine oil: Regularly replace the filter element and engine oil of low-temperature industrial refrigerators to ensure their normal operation.
Related recommendations
How to deal with insufficient water flow in the water cooled chiller?
304How to deal with insufficient water flow in the water cooled chiller? The temperature control of the production process is imbalanced, even leading to severe production problems and acc...
View detailsHow can industrial chiller machine reduce energy consumption?
257How can industrial chiller machine reduce energy consumption? Firstly, we should consider the design and selection of industrial refrigerators. Reasonable design and selection can maxim...
View details-140℃ Ultra-Low Temperature Chiller Startup and Medium Selection
462-140℃ Ultra-Low Temperature Chiller Startup and Medium Selection First, the start-up preparation of the -140°C ultra-low temperature chiller Check whether the relevant protective measures...
View detailsHow to Take Antifreeze Protection Measures for Industrial Chillers in Winter?
670How to Take Antifreeze Protection Measures for Industrial Chillers in Winter? The temperature is low in winter. We know that many machinery and instruments need antifreeze protection measures...
View details
HelloPlease log in