KRY 0 ~ +100°C 1&6 Liquid Cooling System for Battery
Features of Vehicle Test Chillers
- Multi channel output, independent control of flow, no interference with each other.
- Temperature, flow and pressure can be controlled separately.
- Multi channel temperature control, and one device can achieve multi channel output, and control the flow separately.
- Strong circulation pump ensures the delivery of high viscosity liquid, it can provide high flow under stable pressure.
- Clear circuit, compact structure, multiple fault alarm functions to ensure safe operation of the equipment.
- Temperature variation range is usually from -40 to 100 degrees (which can be extended to 150 degrees). While controlling the temperature, you can also choose to control the flow or pressure.
- Equipped with powerful circulating pump to ensure the delivery of high viscosity liquid; Variable frequency regulation or proportional regulation valve is used to control the flow output to achieve high-precision control of 5% ~ 100% of the total range.
- The temperature control equipment can be flexibly connected with other test platforms.
Advantages of Vehicle Test Chillers
Multi Channel Temperature Control
KRY series automotive test chillers support multiple channel temperature control
- Independent flow and pressure control
- temperature, flow and pressure are controlled independently.
Display Function
- Display all the kind of process control temperatures.
- Shows the liquid level of the heat conducting medium in the expansion vessel.
- Shows indication for refrigeration system working.
- Shows indication for heater working.
- Shows indication for circulation pump working.
- Display the temperature control.
- The temperature upper limit, lower limit control can be set.
- The temperature difference between jacket & reactor material can be set.
- Shows the alarm to add the liquid when it is empty.
- The refrigeration compressor can be set to operate manually or automatically.
Data Interface and Software
Standard configuration:
- PT100 temperature sensor input interface.
- USB export data interface.
- RS485 communication interface (MODBUS protocol).
Optional:
- 4 ~ 20mA Input interface for temperature measurement.
- 4 ~ 20mA Input interface for setting temperature.
- Ethernet interface.
- RS232 communication interface (MODBUS protocol).
- Profibus-DP interface.
- Computer operation software (optional Ethernet interface).
Vehicle Performance Test
The new energy vehicle component test unit is mainly used for the offline detection of the drive motor of the new energy vehicle according to relevant test stanards and requuirements, it can test and simulate the performance requirements of motor in actual vehicle operation.
Products Parameters
Noted: Can provide customized services all types of equipment. Please consult us for details.
Model | KRY-A25W/6S | KRY-A38W/6S | KRY-A60W/6S | |
Temp. Range | 0℃~+100℃ | |||
Temp. control precision | ±0.5℃ | ±0.5℃ | ±0.5℃ | |
Temp. feedback | Pt100 | Pt100 | Pt100 | |
Temp. display | 0.01k | 0.01k | 0.01k | |
Flow control/Group | 2~20 L/min | 2~20 L/min | 2~20 L/min | |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L | |
Number of fluid output groups | 6 Groups | 6 Groups | 6 Groups | |
pressure control/Group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
flow pressure description | The equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized) | |||
Heating power | 15kW | 25kW | 38kW | |
cooling capacity | 100℃ | 25kW | 38kW | 60kW |
20℃ | 25kW | 38kW | 60kW | |
5℃ | 18kW | 27kW | 42kW | |
compression | Emerson Valley Wheel Compressor | |||
expansion | Electronic expansion valve | |||
oil distributor | Emerson | |||
Dry filter, Pressure | Danfoss | |||
Evaporator | plate heat exchanger | |||
Ciriulating pump | centrifugal pump can be selected with imported brand magnetic pump | |||
Frequency | Delta | |||
Flow, Pressure sensor | German brand flowmeter, johnson Controls pressure | |||
input, Display | 10 inch color touch screen \ Siemens S7-1200 PLC controller | |||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | |||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | ||||
is it a fully closed system | The whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature. | |||
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available | |||
Connection size | There are six groups of inlet and outlet,G3/4 | |||
Cooling water at 20C° | 6000L/H | 9000L/H | 15000L/H | |
Condenser(W) | Shenshi tube type heat exchanger | |||
Power 380V50HZ | 38kW | 55kW | 82kW | |
Dimension cm | 200*145*205 | 200*145*205 | 200*145*205 | |
Weight | 900kg | 1200kg | 1950kg | |
Optional | 220V 60HZ three phase 460V 60H three phase | |||
Optional | Extend to -40~+135℃ | |||
Optional | The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, | |||
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp. | ||||
Optional | When the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving |
Other Products
KRY 0 ~ +100°C 1&2 Battery Discharge Test
7320 ~ +100°C (optional: -40 ~ +100°C)Temperature Range1.8*2 ~ 60*2kWCooling Capacity9 ~ 120kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen5600 ~ 24000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp …
KRYH 0 ~ +160°C Oil Chillers
7360 ~ +160°C (optional: -40 ~ +100°C)Temperature Range11~ 60kWCooling Capacity22 ~ 68kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen2800 ~ 12000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Fea…
KRYCH -40 ~ +100°C Automotive Battery Test Chamber Chiller
676-40 ~ +100°C (or custom)Temperature Range4 ~ 15kWCooling CapacityR125/R507C/R404ARefrigerant±0.5°CAccuracy7 / 10 inchColor Touch Screen25m³/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Features o…
KRY -40 ~ +100°C 1&2 Fuel Cell Cooling System
678-40 ~ +100°CTemperature Range1.8*2 ~ 60*2kWCooling Capacity30 ~ 158kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen4000 ~ 30000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Vehicle…
loading…