KRY -40 ~ +100°C 1&2 EV Cooling System
Features of Vehicle Test Chillers
- Multi channel output, independent control of flow, no interference with each other.
- Temperature, flow and pressure can be controlled separately.
- Multi channel temperature control, and one device can achieve multi channel output, and control the flow separately.
- Strong circulation pump ensures the delivery of high viscosity liquid, it can provide high flow under stable pressure.
- Clear circuit, compact structure, multiple fault alarm functions to ensure safe operation of the equipment.
- Temperature variation range is usually from -40 to 100 degrees (which can be extended to 150 degrees). While controlling the temperature, you can also choose to control the flow or pressure.
- Equipped with powerful circulating pump to ensure the delivery of high viscosity liquid; Variable frequency regulation or proportional regulation valve is used to control the flow output to achieve high-precision control of 5% ~ 100% of the total range.
- The temperature control equipment can be flexibly connected with other test platforms.
Advantages of Vehicle Test Chillers
Multi Channel Temperature Control
KRY series automotive test chillers support multiple channel temperature control
- Independent flow and pressure control
- temperature, flow and pressure are controlled independently.
Display Function
- Display all the kind of process control temperatures.
- Shows the liquid level of the heat conducting medium in the expansion vessel.
- Shows indication for refrigeration system working.
- Shows indication for heater working.
- Shows indication for circulation pump working.
- Display the temperature control.
- The temperature upper limit, lower limit control can be set.
- The temperature difference between jacket & reactor material can be set.
- Shows the alarm to add the liquid when it is empty.
- The refrigeration compressor can be set to operate manually or automatically.
Data Interface and Software
Standard configuration:
- PT100 temperature sensor input interface.
- USB export data interface.
- RS485 communication interface (MODBUS protocol).
Optional:
- 4 ~ 20mA Input interface for temperature measurement.
- 4 ~ 20mA Input interface for setting temperature.
- Ethernet interface.
- RS232 communication interface (MODBUS protocol).
- Profibus-DP interface.
- Computer operation software (optional Ethernet interface).
Vehicle Performance Test
The new energy vehicle component test unit is mainly used for the offline detection of the drive motor of the new energy vehicle according to relevant test stanards and requuirements, it can test and simulate the performance requirements of motor in actual vehicle operation.
Products Parameters
Noted: Can provide customized services all types of equipment. Please consult us for details.
Model | KRY-475/2S | KRY-4A15W/2S | KRY-4A25W/2S | KRY-4A38W/2S | KRY-4A60W/2S | |
KRY-475W/2S | ||||||
Temp Range | -40℃~+100℃ | |||||
Temperature control precision | ±0.5℃ | |||||
Temperature feedback | Pt100 | |||||
Temperature display | 0.01k | |||||
Flow control/Group | 1~20 L/min | 1~20 L/min | 1~20 L/min | 1~40 L/min | 1~40 L/min | |
Flow control accuracy/Group | ±0.2L | ±0.2L | ±0.2L | ±0.2L | ±0.2L | |
Number of fluid output groups | 2 groups | 2 groups | 2 groups | 2 groups | 2 groups | |
Pressure control/group | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | 0.2bar~2.5bar | |
Flow description | When the temperature control is lower than -30℃, the flow rate is controlled within 80% of the maximum value. | |||||
Flow pressure description | The unit can control the flow individually or separately. Need to control different solutions at the same time (customized) | |||||
Heating Power | 10kW | 15kW | 15kW | 25kW | 38kW | |
Cooling capacity | 100℃ | 10kW | 15kW | 25kW | 38kW | 60kW |
20℃ | 10kW | 15kW | 25kW | 38kW | 60kW | |
0℃ | 10kW | 15kW | 25kW | 38kW | 60kW | |
-20℃ | 6kW | 8.5kW | 14kW | 22kW | 35kW | |
-35℃ | 2.5kW | 4kW | 6.5kW | 10kW | 15kW | |
Compression | Emerson Valley Wheel Compressor | |||||
Expansion valve/solenoid valve | Electronic expansion valve | |||||
Oil distributor | Emerson | |||||
Dry filter, Pressure control | Danfoss | |||||
Evaporator | plate heat exchanger | |||||
Circulating pump | Magnetic drive pump | |||||
Frequency converter | Delta | |||||
Flow,Pressure sensor | Electromagnetic flowmeter, Johnson Controls pressure sensor | |||||
Input, Display | 10 inch color touch screen \ Siemens S7-1200 PLC controller | |||||
Communication | Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol | |||||
Safety protection | With self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection | |||||
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions | ||||||
Closed circulation system | The whole system is a fully closed system, there will be no oil mist at high temperature, low temperature does not | |||||
absorb water in the air, the system in operation will not because of high temperature pressure rise, low temperature | ||||||
automatically add heat conduction medium. | ||||||
refrigerant | R404A/R507C/R125/N40 All four refrigerants are available | |||||
Connection size | There are two groups of inlet and outlet, G3/4 | |||||
Cooling water@20C | 2500L/H | 4000L/H | 8000L/H | 12000L/H | 18000L/H | |
Condenser(W) | Shenshi tube type heat exchanger | |||||
Condenser(A) | Optional air-cooled type, upper air outlet, the equipment size will be increased. | |||||
Power 380V50HZ | 17kW | 25kW max | 36kW max | 56kW max | 81kW max | |
Dimension cm | 70*100*175 | 80*120*185 | 100*150*185 | 120*180*205 | 145*205*225 | |
Weight(W) | 360KG | 450kg | 750kg | 1000kg | 1700kg | |
Optional | 220V 60HZ Three phase 400V 50HZ Three phase 440V 60HZ Three phase | |||||
Optional | Extend to -40~+135℃ | |||||
Optional | The size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load, | |||||
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp. |
Other Products
KRYCH -40 ~ +100°C Automotive Battery Test Chamber Chiller
677-40 ~ +100°C (or custom)Temperature Range4 ~ 15kWCooling CapacityR125/R507C/R404ARefrigerant±0.5°CAccuracy7 / 10 inchColor Touch Screen25m³/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Features o…
KRY -40 ~ +100°C 1&6 Lithium Ion Battery Cooling System
607-40 ~ +100°CTemperature Range5 ~ 60kWCooling Capacity38 ~ 82kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen8000 ~ 18000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Vehicle Test C…
KRY-O +5 ~ +135°C Oil Chiller Systems
742+5 ~ +135°C (optional: -40 ~ +100°C)Temperature Range15 ~ 38kWCooling Capacity63A ~ 125ACircuit Breaker±0.3°CAccuracy7 / 10 inchColor Touch Screen4000 ~ 8500L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp …
ZLJ Direct Cooling Chillers
701Air CooledCooling Type5 ~ 10kWCooling CapacityR134ARefrigerant380V 50HZPower SupplyPLC ControllerControl System CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Direct Cooling Chillers The automoti…
loading…