LTS -20 ~ +80°C Semiconductor Chip Testing
Features of Semiconductor Chillers
- The pressure holding test of the medium circulation system is 7 bar.
- Use high-quality magnetic pump without mechanical shaft seal.
- Optimize temperature sampling and response speed, specially designed control algorithm, can respond quickly to stable temperature control.
- Enhance the design of circulating pump capacity to meet the high-lift requirements of the system.
- Continuous high temperature cooling technology meets the requirements of stable operation when heat is loaded on the heat sink plate and requires constant temperature control of cooling and heating.
- In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.
Advantages of Semiconductor Chillers
Display Function
- Display all the kind of process control temperatures.
- Shows the liquid level of the heat conducting medium in the expansion vessel.
- Shows indication for refrigeration system working.
- Shows indication for heater working.
- Shows indication for circulation pump working.
- Display the temperature control.
- The temperature upper limit, lower limit control can be set.
- The temperature difference between jacket & reactor material can be set.
- Shows the alarm to add the liquid when it is empty.
- The refrigeration compressor can be set to operate manually or automatically.
Data Interface and Software
Standard configuration:
- PT100 temperature sensor input interface.
- USB export data interface.
- RS485 communication interface (MODBUS protocol).
Optional:
- 4 ~ 20mA Input interface for temperature measurement.
- 4 ~ 20mA Input interface for setting temperature.
- Ethernet interface.
- RS232 communication interface (MODBUS protocol).
- Profibus-DP interface.
- Computer operation software (optional Ethernet interface).
Configuration Software (Optional)
All dynamic temperature control system can be connected with the computer.
You can install and record the picture of display on the computer via the configuration software.
- Communication distance less than 200m.
- Easily temperature setting.
- Real time control screen.
- Curve records.
- Program selection.
- Alarm screen recording.
Products Parameters
Noted: Can provide customized services all types of equipment. Please consult us for details.
Model | LTS-202 | LTS-203 | LTS-204 | LTS-206 | LTS-208 |
LTS-202W | LTS-203W | LTS-204W | LTS-206W | LTS-208W | |
Temperature range | -20℃~80℃ | ||||
Temperature control accuracy | ±0.1℃ at -20℃~0℃ | ||||
Flow control | 7~25L/min | 12~45L/min | |||
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar. | |||||
Internal circulating fluid volume | 4L | 5L | 6L | 8L | 10L |
Expansion tank volume | 10L | 10L | 15L | 15L | 20L |
System pressure display | The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure) | ||||
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen | |||||
Controller | Siemens PLC, fuzzy PID control algorithm, with cascade control algorithm | ||||
Temperature control | Heat transfer medium outlet temperature control mode | ||||
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control) | |||||
Letter of agreement | Ethernet interface TCP/IP protocol | ||||
RS485 interface modbus RTU protocol | |||||
Internal temperature feedback of equipment | Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment) | ||||
Closed circulation system | The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system | ||||
Compressor | Emerson Copeland/Danfoss Scroll Flexible Compressor | ||||
Circulating pump | German brand magnetic circulation pump | ||||
Evaporator | Adopt Danfoss/Gaoli plate heat exchanger | ||||
Condenser | Micro channel condenser (air-cooled) | ||||
Plate heat exchanger (water-cooled), special attention: clean factory water is required | |||||
Refrigeration accessories | Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve) | ||||
Operation panel | Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export | ||||
Security | With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions. |
Other Products
LTS -80 ~ +80°C Semiconductor Test Equipment
721-80 ~ +80°CTemperature Range10 ~ 20LExpansion Valve7 ~ 45L/minFlow Control±0.1°CAccuracy7 / 10 inchColor Touch Screen CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Semiconductor Chillers The pres…
LTS -40 ~ +80°C Semiconductor Refrigeration System
665-40 ~ +80°C (optional: -80 ~ +80°C)Temperature Range10 ~ 20LExpansion Valve7 ~ 45L/minFlow Control±0.1°CAccuracy7 / 10 inchColor Touch Screen CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Semiconduct…
LTS -60 ~ +80°C Refrigeration Chip
645-60 ~ +80°C (optional: -80 ~ +80°C)Temperature Range10 ~ 20LExpansion Valve7 ~ 45L/minFlow Control±0.1°CAccuracy7 / 10 inchColor Touch Screen CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Semiconduct…
loading…
已经是到最后一篇内容了!