Six Suggestions for Chiller Selection

Unitization of refrigeration system is the development direction of modern refrigeration equipment. The chiller is a refrigeration unit that assembles all or part of the refrigeration equipment into a whole and directly supplies the required refrigerant water to the user.

There are many types of chillers, and the applicable environments and uses of different chillers are also different. The following are our six suggestions for chiller selection:

  1. Refrigeration system load = indoor load + reheat load + fresh air load. If the total load of the air-conditioning system is calculated from the estimated index of the air-conditioning load, then the load of the refrigeration system = the total load of the air-conditioning system.   
  2. When selecting an electric-driven chiller, when the cooling capacity of a single air conditioner is Q>1163kw, a centrifugal chiller should be selected: when Q=580-1163kw, a centrifugal or screw chiller should be selected: when Q<580kw , Piston chillers should be used. When the average outdoor temperature in winter is higher than -10°C, the heat pump chiller can be used.   
  3. The COP of the refrigeration system of the electric-driven refrigerator is about three times higher than that of the thermal system of the absorption refrigerator. The order of consumption from low to high is: centrifugal type, screw type, piston type, absorption type. Therefore, only when there is a suitable heat source, especially in places where waste heat or waste heat can be used, or in places where electricity is lacking, should the absorption chiller be selected.   
  4. It is generally advisable to choose 2-4 chillers, 2 sets for small and medium scale, 3 sets for larger scale, and 4 sets for extra large scale. The possibility of mutual backup and alternate use should be considered among the units. In the chiller machine room, a combined scheme of unit deployment with different capacities can be adopted to save energy consumption.   
  5. Environmental pollution should be considered when selecting chillers: first, noise and vibration, to meet the requirements of the surrounding environment; second, the degree of harm of refrigerants to the atmospheric ozone layer and the size of the greenhouse effect.   
  6. Regarding the selection of the number of chillers, try to avoid the selection of a single chiller. If conditions permit, two or more chillers can be selected. In this way, the standby chiller can be ignored, and the load changes.

Latest News

  • liquid cooled chiller

    3

    Liquid-Cooled Chillers: High-Performance Cooling for Industrial Applications Introduction Liquid-cooled chillers are increasingly becoming the cooling solution of choice in various industries due to their superior heat transfer capabilities…

  • glycol water cooling system

    4

    Glycol Water Cooling Systems: Design, Efficiency, and Maintenance Introduction Glycol water cooling systems are widely used in various industries for their ability to cool equipment effectively while operating in a wide range of ambient tem…

  • cold water cooling system

    4

    Cold Water Cooling Systems: Design and Efficiency Introduction Cold water cooling systems are vital in industries such as manufacturing, pharmaceuticals, and data centers, where they help regulate temperatures for processes and equipment. T…

  • air cooled fluid cooler

    4

    Air-Cooled Fluid Coolers: Design, Operation, and Efficiency Introduction Air-cooled fluid coolers are essential in various industrial processes for their ability to maintain fluid temperatures. They operate by transferring heat from the flu…

loading…

已经是到最后一篇内容了!