ZLJ Direct Cooling Heating Systems

Features of Direct Cooling Heating Systems
The automotive direct cooling and direct heating system is mainly used in the battery field, which can directly cool the battery cell, module and battery pack through the refrigerant liquid during the charge and discharge test. Compared with the current natural cooling or air cooling and liquid cooling, the direct cooling system does not require secondary heat exchange and is the best cooling method. The heat exchange efficiency is high, the temperature range is wide and the equipment structure is simple, and it is very convenient to use.
Products Parameters
Noted: Can provide customized services all types of equipment. Please consult us for details.
Model | ZLJ-2.5P-H | ZLJ-4P-H |
Cooling Capacity | 5kw | 10kw |
Heating Capacity | 6kw | 12kw |
Refrigerant | R134a | R134a |
Inhalation pressure (according to the actual battery pack matching control) | 300kpa | 300kpa |
Suction pressure control accuracy | ±30kpa | ±30kpa |
Condensing pressure | 1600kpa | 1600kpa |
Condensing pressure control accuracy | ±50kpa | ±50kpa |
Pressure Measurement Resolution | 0.1kpa | 0.1kpa |
Temperature measurement resolution | 0.1℃ | 0.1℃ |
Subcooling degree (expansion valve front end temperature) | 0℃~6℃ | 0℃~6℃ |
Superheat (battery pack outlet temperature) | 0℃~5℃ | 0℃~5℃ |
Exhaust superheat degree (direct heat compressor to condenser inlet) | 0℃~5℃ | 0℃~5℃ |
Direct thermal condensing pressure (condenser inlet pressure) | 1500kpa | 1500kpa |
Direct heat subcooling degree (condenser outlet temperature) | 3℃~5℃ | 3℃~5℃ |
Cooling method | air cooled | air cooled |
Compressor | Inverter compressor | Inverter compressor |
Screen display | Display control pressure, superheat (battery pack outlet temperature), subcooling (expansion valve front end temperature), equipment inlet and outlet exhaust pressure and suction pressure, exhaust temperature and suction temperature, the above data are displayed in real-time curves, and can be viewed Historical data and export. | |
Control System | PLC | PLC |
Communication | CAN | CAN |
Noise | ≤75dB(A) | ≤75dB(A) |
Power supply | 380V/50HZ | 380V/50HZ |
Optional | Optional mass flow meter, refrigerant filling and recovery integrated machine |
Other Products
KRY -40 ~ +100°C 1&2 Fuel Cell Cooling System
1136-40 ~ +100°CTemperature Range1.8*2 ~ 60*2kWCooling Capacity30 ~ 158kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen4000 ~ 30000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Vehicle…
ZLJ Direct Cooling Chillers
1143Air CooledCooling Type5 ~ 10kWCooling CapacityR134ARefrigerant380V 50HZPower SupplyPLC ControllerControl System CUSTOM DESIGN Leave a Message Email Us WhatsApp Features of Direct Cooling Chillers The automoti…
KRY 0 ~ +100°C 1&2 Battery Discharge Test
13180 ~ +100°C (optional: -40 ~ +100°C)Temperature Range1.8*2 ~ 60*2kWCooling Capacity9 ~ 120kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen5600 ~ 24000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp …
KRY 0 ~ +100°C 1&2 Battery Liquid Cooling System
12090 ~ +100°C (optional: -40 ~ +100°C)Temperature Range7 ~ 60kWCooling Capacity17 ~ 65kWPower±0.5°CAccuracy7 / 10 inchColor Touch Screen2600 ~ 15000L/HCooling Water CUSTOM DESIGN Leave a Message Email Us WhatsApp Fea…
loading…
已经是到最后一篇内容了!