Temperature Forcing Systems
Suitable for IC testing of all kinds of semiconductor chips, flash memory Flash/EMMC, PCB circuit boards, optical communications, electronic industries, etc.
It can isolate one IC or original component among many components and separately perform high and low temperature impact without affecting other surrounding device. Compared with the traditional thermal shock test box, the temperature impact rate is faster.
Model | Cooling Water | Accuracy | Power |
m³ | ℃ | kW | |
AES -115 ~ +225℃ series | 0.6 ~ 3 | ±0.5 ~ ±1 | 3.7 ~ 7.5 |
- Temperature range: -120 ℃ ~ +300 ℃.
- The temperature rise and fall is very fast, -55 ℃ ~ 150 ℃ < 10 seconds.
- Temperature control accuracy: ±1 ℃.
- Temperature setting capability: ±0.1 ℃.
- Temperature display capability: ±0.1 ℃.
- Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time.
- The temperature rise and fall time is controllable, programmable operation, manual operation and remote control.
- Widely used in semiconductor companies, aerospace, optical communications, universities, research institutes and other fields.
- Provides accurate and fast ambient temperature (-120 °C ~ +300 °C) for chips, modules, integrated circuit boards, and electronic components. It is an indispensable instrument for product electrical performance testing, failure analysis, and reliability assessment.
- It can isolate one IC or original component among many components and separately perform high and low temperature impact without affecting other surrounding device. Compared with the traditional thermal shock test box, the temperature impact rate is faster.
- Laboratories / Research Institutes
- Universities / Colleges
- Aerospace industry
- Automotive Industry
- Semiconductor and Electrical Industry
- Chemical / Pharmaceutical Industry
- Petrochemical Industry
- Biochemical Industry
- Medical Industry
- Plastics Industry
- Hospitals
- Cannabis
- R&D Workshop
- Biotechnology Industry
- Other Industries
Gas Cooler
It is used to cool the gas (without corrosion): normal temperature gases such as dry compressed air, nitrogen and argon are introduced into LQ series equipment, and the gas can reach the target low temperature and be supplied to the components or heat exchangers for demand test.
Model | Air Flow Rate | Heat Exchanger Area | Power |
m³/h | ㎡ | kW | |
LQ -110 ~ -40℃ series | 15 ~ 100 | 0.8 ~ 13 | 1.2 ~ 11.5 |
- Gas heat transfer system withstands pressure of 25bar.
- The temp ranges from -40℃~-75 ℃, which can meet different temp.
- Environmentally friendly refrigerants are used.
- Secondary supercooling technology is adopted to ensure rapidrefrigeration and low limit temperature.
- Adopt imported famous brand fully closed, demi-closed pistoncompressor, scroll flexible compressor. mainly from Carlisle,Tecumseh,Emerson.
- Double tube heat exchanger is chosen for the cold box, which hassmall volume, long residence time and high efficiency.
- Adopt a full set of improt cold control (Danfoss pressure controller,balance valve, expansion valve,solenoid valve, drying filter, Emersonoil separator, ALCO view mirror, one-way valve, etc.).
- Danfoss expansion valve and Tmerson electroic expansion valve.
- Siemens S7 PLC,7-inch touch screen, automatic control operation,
- temperature curve display, temperature record U disk, fault alarm record.
- Factory test: Each unit is tested with load in the factory for no less than12 hours.
- The temperature range of the equipment is -110 ℃ ~ -40 ℃, using environmentally friendly refrigerant, the cooling speed is fast. The products use branded compressors, mainly Carlisle and Emerson. Adopt a full set of high-quality cold control (Danfoss pressure controller, balance valve, expansion valve, solenoid valve, filter drier, Emerson oil separator, alco liquid sight glass, check valve, etc).
- It adopts Siemens S7 PLC and 7-inch touch screen for automatic control operation, and provides temperature curve display, temperature record U disk and fault alarm record. Each piece of equipment is subjected to a load test at the factory, and the test time is not less than 12 hours.
- Laboratories / Research Institutes
- Universities / Colleges
- Aerospace industry
- Automotive Industry
- Semiconductor and Electrical Industry
- Chemical / Pharmaceutical Industry
- Petrochemical Industry
- Biochemical Industry
- Medical Industry
- Plastics Industry
- Hospitals
- Cannabis
- R&D Workshop
- Biotechnology Industry
- Other Industries
Recirculating Air Temperature Control System
It is widely used in high and low temperature testing of semiconductor equipment. Cold and heat sources for high temperature and low temperature constant temperature test of electronic equipment
Model | Cooling Capacity | Heating Capacity | Circulating Air Flow | Power |
kW | kW | m³/h | kW | |
AI -105 ~ +125℃ series | 1 ~ 3.5 | 3.5 | 550 | 7 ~ 9.5 |
- It is widely used in high and low temperature testing of semiconductor equipment. Cold and heat sources for high temperature and low temperature constant temperature test of electronic equipment;
- Independent refrigeration cycle fan unit;
- It can work continuously for a long time and defrost automatically. The defrosting process does not affect the storage temperature;
- Modular design, easy replacement of standby unit (if there are 10 units, only one standby unit can be used);
- Solve the problem of frequent door opening and closing and frosting of evaporation system; The defrosting process of the evaporation system has no influence.
- It is simple to build a set of high and low temperature constant temperature chamber transformer (according to the drawings provided, the box shall be spliced like building blocks, the electricity and water shall be connected, and the work can be started after the temperature is set).
- It is widely used in high and low temperature testing of semiconductor equipment. Cold and heat sources for high temperature and low temperature constant temperature test of electronic equipment. It can work continuously for a long time and defrost automatically. The defrosting process does not affect the storage temperature.
- Modular design, easy replacement of standby unit (if there are 10 units, only one standby unit can be used). It is simple to build a set of high and low temperature constant temperature chamber transformer (according to the drawings provided, the box shall be spliced like building blocks, the electricity and water shall be connected, and the work can be started after the temperature is set).
- Laboratories / Research Institutes
- Universities / Colleges
- Aerospace industry
- Automotive Industry
- Semiconductor and Electrical Industry
- Chemical / Pharmaceutical Industry
- Petrochemical Industry
- Biochemical Industry
- Medical Industry
- Plastics Industry
- Hospitals
- Cannabis
- R&D Workshop
- Biotechnology Industry
- Other Industries