1、 Electrical fault
Starting the compressor of the cold water cooler requires the support of electrical signals. If the electrical accessories fail or the wiring is poor, it will cause the compressor to fail to start. At this time, it is necessary to check whether the power input is normal, whether the electrical components are damaged or whether the wiring is correct. If a malfunction is found, it needs to be replaced or repaired in a timely manner.
2、 Pressure sensor failure
The pressure sensor of the cold water cooler is mainly used to detect the pressure status of the compressor. If the sensor is damaged or fails, it will cause the compressor to fail to start. At this point, it is necessary to check whether the sensor is clean and in good contact. If the problem cannot be solved, the sensor needs to be replaced.
3、 Overload protector disconnected
The overload protector of the cold water cooler is a safety protection device. If the compressor is overloaded or the temperature is too high, the overload protector will automatically disconnect the power supply, thereby protecting the compressor from damage. However, if the protector is damaged or too sensitive, it can also cause the compressor to fail to start. At this point, it is necessary to check the status of the protector. If any abnormalities are found, the overload protector needs to be replaced.
In summary, the reasons for the cold water cooler compressor not starting may be multifaceted and require targeted inspection and maintenance. If the user does not have relevant experience, it is recommended to invite professional personnel for inspection and maintenance to avoid unnecessary losses.
Related recommendations
The Difference between Open Chiller and Water-cooled Box Chiller
917The Difference between Open Chiller and Water-cooled Box Chiller Everyone knows that chillers can be classified in various and complicated ways. It is mainly divided into two types: air-coole...
View detailsHow to deal with oil leakage in small water chiller?
455How to deal with oil leakage in small water chiller? 1. There are no traces of oil in the oil separator, that is, the oil is not collected in the condenser, but enters the evaporator th...
View detailsglycol water cooling system
4Glycol Water Cooling Systems: Design, Efficiency, and Maintenance Introduction Glycol water cooling systems are widely used in various industries for their ability to cool equipment effectiv...
View detailsAdvantages of Air Cooled Chillers
611Advantages of Air Cooled Chillers Configuration of air-cooled chillerAccording to the compressor, the air-cooled chiller can be divided into an air-cooled scroll chiller and an air-cooled sc...
View details
HelloPlease log in