What should be done if the compressor of an chiller industrial is burned out?
What should be done if the compressor of an chiller industrial is burned out?
1. The reason for the burning of the LC -25 ~ -5°C Water Chillers compressor may be due to a lack of phase in the power supply. It can be confirmed by checking if one or both phases in the winding have turned black and if the coil is damaged;
2. The reason for the burning of the industrial refrigeration compressor may be that the contactors and contact points in the circuit are not closed, and the connection points of the wires are loose;
3. The reason for the burning of the industrial refrigeration compressor may be due to the overload of the motor, resulting in prolonged overcurrent and overheating operation of the motor;
The reason why the compressor of an industrial refrigerator is burned out may be due to frequent starting and braking of the refrigerator.
If it has been determined that the compressor is damaged and completely unusable, we should replace it with a new one as follows:
Remove the drying filter and use a temporary detachable connecting pipe or copper pipe joint to connect the short circuit part;
Inject the cleaning agent into the Plumbing to clean and circulate. If necessary, replace the cleaning agent for multiple cleaning;
Blow dry the entire system with nitrogen gas at a pressure of 10kg/cm2 until there is no residual cleaning agent;
Install a good compressor and drying filter, and use nitrogen gas with a pressure of 10kg/cm2 to detect leakage. If there is no leakage, the remaining nitrogen gas can be discharged into the atmosphere through the high-pressure corner valve.
What should be paid attention to when using industrial chillers?
Place the chiller in a shaded and naturally ventilated application. The operating temperature of the chiller should not be too high, and the operating temperature should be maintained at no more than 40 ℃.
The fan of the chiller has a heat removal function. Regularly maintain the operation of the fan, and dismantle the cover net of the chiller on time. Use a pneumatic gun to remove dust and dirt from the edge of the cover net.
Note that the distance between the chiller and the road barrier should not be too close. The distance between the air vent (fan) of the chiller and the obstruction should be maintained at least 1.5m, and the distance between the inlet and outlet (soil cover) and the obstruction should be maintained at least 1m.
Disassemble and replace the cooling circulating water of the chiller on time, and it is proposed to replace it every three months. Due to the excessive residue in drinking water, it is very easy to cause blockage in the circulation system pipeline and is not recommended for use. Suggest using mineral water or purified water as the cooling circulating water for the chiller.
Proper daily maintenance and upkeep of the chiller not only improves cooling efficiency, but also increases the lifespan of the chiller.
Related recommendations
industrial chiller units for sale
664Industrial Chiller Units for Sale: An In-Depth Overview Industrial chiller units are indispensable in numerous industries for maintaining optimal temperatures in processes such as chemical proc...
View detailsportable water chiller system
808Portable Water Chiller System: A Comprehensive Guide Water is an essential resource, and its temperature can significantly impact various applications, from industrial processes to personal com...
View detailsindustrial heating manufacturers
451What Are Industrial Heating Manufacturers?Industrial heating manufacturers are companies that design, produce, and supply heating equipment for industrial applications. These manufacturers develop...
View detailssmall water chiller unit
860Small Water Chiller Units: Efficient Cooling for Limited Spaces Small water chiller units are increasingly becoming the cooling system of choice for a variety of applications where space is at ...
View details
LNEYA Chiller





HelloPlease log in