How to Extend the Life of the Water Cooled Chiller?
After customers use the chiller for a long time, if they do not carry out good maintenance, it is inevitable that various failures will occur in the future use. So, how do we usually maintain the water-cooled chiller to ensure its normal use and even prolong its service life? Below, I will share with you the maintenance skills of water-cooled chillers based on the introduction of technicians.
- When installing a water-cooled chiller, be sure to choose an area with a flat, solid floor that can bear the weight of the unit, and a good ventilation environment. Take shock absorption and stabilization measures for chillers, water pumps, and cooling towers to avoid vibration movement caused by unit startup. The diameter of the water pipes connecting each equipment should match the equipment. At one end of the chiller, there should be a clear draining space for the condenser tube bundle, which is convenient for the later maintenance of the chiller.
- Before using the water-cooled chiller, the operator must have certain operating knowledge and basic experience. If not, the operator should be prohibited from using it. Before use, the operator needs to read the instruction manual of the equipment in detail, and operate in strict accordance with the content inside, especially the initial installation and debugging work.
- In the process of using the water-cooled chiller, the operator must use it strictly in accordance with the instructions in the manual. For the unknown or uncertain place, he must consult the relevant engineer or the chiller manufacturer. After the installation and commissioning of the chiller is completed, it can be officially put into operation. The operator should carefully observe whether the pipeline connection, water flow rate, unit cooling, etc. between the various equipment are normal, so as to avoid unnecessary damage to the equipment caused by errors.
- Many customers run the water-cooled chiller 24 hours a day, but some customers will stop the operation halfway. I would like to remind everyone to stop the operation of the chiller according to the normal shutdown steps, clean the unit, and regularly check the refrigerant and lubricating oil of the equipment, so as to find out the leaks and repair them in time, so as to avoid causing more damage to the unit. .
- When the unit runs for one year, the water-cooled chiller must be maintained, such as line inspection, cooling tower cleaning, condenser cleaning, pipeline cleaning, filter replacement, system maintenance, etc. Only regular maintenance of any equipment can prolong its service life.
Latest News
liquid cooled chiller
3Liquid-Cooled Chillers: High-Performance Cooling for Industrial Applications Introduction Liquid-cooled chillers are increasingly becoming the cooling solution of choice in various industries due to their superior heat transfer capabilities…
glycol water cooling system
4Glycol Water Cooling Systems: Design, Efficiency, and Maintenance Introduction Glycol water cooling systems are widely used in various industries for their ability to cool equipment effectively while operating in a wide range of ambient tem…
cold water cooling system
4Cold Water Cooling Systems: Design and Efficiency Introduction Cold water cooling systems are vital in industries such as manufacturing, pharmaceuticals, and data centers, where they help regulate temperatures for processes and equipment. T…
air cooled fluid cooler
4Air-Cooled Fluid Coolers: Design, Operation, and Efficiency Introduction Air-cooled fluid coolers are essential in various industrial processes for their ability to maintain fluid temperatures. They operate by transferring heat from the flu…
loading…
已经是到最后一篇内容了!