How to Maintain the Chiller in Winter?
The changes brought by the cooler weather remind people to pay attention to the winter maintenance of the chiller, and slowly adapt to the temperature difference brought by the cold air.
- Check the setting of the chiller switch button and confirm the equipment status when the high pressure switch is on;
- Check the oil level in the oil tank of the chiller, replace the condenser if necessary, check the scale of the refrigerant oil, and ensure the operation of the compressor;
- Check the refrigeration oil filter, and if necessary, check the chiller to clean the heat transfer tube. The condensing pressure is too high, and whether the water treatment of the high-pressure ring system of the condenser of the unit is normal;
- Clean the heat transfer tube to avoid scratching and scraping the tube wall;
- Disassemble the safety valve at least once every six months to see if there is corrosion, rust, scaling, etc. inside it. If corrosion or leakage is found, the safety valve must be replaced;
- Check the cleaning cycle and water circulation of the condenser/evaporator tube side. If you see serious scaling, it must be cleaned. Replace the cleaning equipment with new ones at least once every six months. Insufficient cooling capacity is usually caused by scaling in the pipe or air in the unit. If the difference between the temperature and the outlet water temperature is greater than 5°C, the condensing pipe may be scaled.
- Check the record table of the number of chillers to see if the special brushes from the factory are used and whether there is any abnormal phenomenon;
- Check whether there is leakage or insulation between the windings of the compressor motor;
Latest News
water chiller efficiency
129Introduction to Water Chiller Efficiency Water chillers are vital refrigeration systems that cool water (or water-glycol mixtures) for air conditioning, industrial processes (e.g., manufacturing, data center cooling), and equipment temperatur…
chiller rate
145Introduction to Chiller Rate Chiller rate is a collective term describing the performance metrics that quantify a chiller’s ability to remove heat (cooling capacity) and its efficiency in doing so. Chillers are refrigeration systems that cool…
closed cycle cryocooler
200Introduction to Closed Cycle Cryocoolers Closed cycle cryocoolers (CCCs) are specialized thermal management systems engineered to generate and sustain temperatures far below ambient, typically ranging from 0.1 K to 120 K (-273.05 °C to -153.1…
water cooled chiller types
204Working PrincipleReciprocating water cooled chillers use reciprocating compressors. These compressors operate through the back – and – forth motion of a piston within a cylinder. The refrigerant is drawn into the cylinder during the intake strok…
loading…
已经是到最后一篇内容了!
LNEYA Chiller