Reasons and Solutions for Industrial Chillers not Cooling

    With the development of science and technology, industrial chillers have become refrigeration equipment in industrial production, so the failure of industrial chillers to cool will affect the normal operation of the equipment. When the industrial chiller does not refrigerate during use, how do we solve it?
    1. The filter screen of the industrial chiller is blocked. When the filter screen is blocked, the dust on the condenser will accumulate more and more, which will affect the cooling effect of the refrigeration equipment over time. In the long run, it may even cause the industrial chiller to be unable to cool.
    Solution: Clean the filter regularly.
    2. The cooling liquid content of the industrial chiller is small, and the cooling liquid content is too small, the equipment will not be able to absorb oil, and the cooling effect will be reduced.
    Solution: Check the coolant frequently to see if the coolant level is maintained between high and low, and add coolant in time when the coolant is too low.
    3. The industrial chiller lacks Freon. In some early refrigeration equipment that uses Freon as a refrigerant, Freon will volatilize after a long time of use, thus affecting the cooling effect.
    Solution: Freon may be harmful to the human body, so in this case, you should find a professional maintenance company to add it. How to judge the lack of fluorine in an industrial chiller? The main manifestations are low fluorine pressure, decreased cooling capacity, increased return air temperature, increased exhaust temperature, or natural evaporation pressure. If it doesn’t cool down and the evaporating pressure is low, check for leaks. But there may also be other reasons.
    The reason for the failure of the industrial chiller to be able to cool may also be that the power supply voltage is low or the power of the cooling equipment is not enough. If the industrial chiller fails, the enterprise must use professional methods to complete the troubleshooting in time to ensure the safe and stable operation of the industrial chiller, and regularly check whether the various components of the industrial chiller are worn or damaged, which should be replaced in time. In addition, when enterprises purchase industrial chillers, they should reasonably match the chillers according to production needs, so as to better use the industrial chillers and reduce the cost of enterprise use.
    The reasons and solutions for the inability of industrial chillers to be refrigerated are shared here. If this phenomenon occurs in industrial chillers, it is generally inseparable from the above-mentioned reasons. However, if you still fail to solve the problem after following the methods analyzed above, it is recommended that you directly contact the industrial chiller manufacturer for inspection and maintenance to avoid larger failures.

        Latest News

        • water chiller efficiency

          129

          Introduction to Water Chiller Efficiency​ Water chillers are vital refrigeration systems that cool water (or water-glycol mixtures) for air conditioning, industrial processes (e.g., manufacturing, data center cooling), and equipment temperatur…

        • chiller rate

          145

          Introduction to Chiller Rate​ Chiller rate is a collective term describing the performance metrics that quantify a chiller’s ability to remove heat (cooling capacity) and its efficiency in doing so. Chillers are refrigeration systems that cool…

        • closed cycle cryocooler

          200

          Introduction to Closed Cycle Cryocoolers​ Closed cycle cryocoolers (CCCs) are specialized thermal management systems engineered to generate and sustain temperatures far below ambient, typically ranging from 0.1 K to 120 K (-273.05 °C to -153.1…

        • water cooled chiller types

          204

          Working Principle​Reciprocating water cooled chillers use reciprocating compressors. These compressors operate through the back – and – forth motion of a piston within a cylinder. The refrigerant is drawn into the cylinder during the intake strok…

        loading…

        已经是到最后一篇内容了!